Accumulator Capacity Estimation Guide for Hydraulic Pump Pulsations

Estimating the accumulator capacity required to absorb hydraulic pump pulsations requires consideration of various factors, including the characteristics of the hydraulic system and the required level of pulsation reduction. Accumulators are used to store hydraulic fluid under pressure and release it when pump output falls below system demand, helping to eliminate pressure pulsations. Here is a step-by-step guide to estimating the required accumulator capacity:

1. Define system parameters:
Determine the pump flow rate (Qp) in liters per minute (LPM) or gallons per minute (GPM).
Calculate the pump's output pressure pulsation frequency (f) in cycles per minute (CPM).

2. Determine the pulsation amplitude (ΔP):
Measures the maximum and minimum pressure (usually measured in bar or psi) in a hydraulic system during the entire cycle of the pump.
Calculate the pressure pulsation amplitude (ΔP) according to the following formula:
ΔP=(maximum pressure-minimum pressure)/2

3. Determine the required pulsation reduction:
Decide what percentage of pulsation reduction you want to achieve. Typically, a 10-20% reduction is considered effective in many applications.

4. Calculate the required battery capacity (V):
Use the formula:
V=(Qp*ΔP)/(f*ΔP expected reduction)

V is the required accumulator capacity in liters or gallons.
H1-P-165-R-C-A-A5-C2-N-D9-G-G2-H4-L-30-L-30-L-L-24-PN-NNN-NNN H1P165RCAA5C2ND9GG2H4L30L30LL24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D8-G-G3-NN-L-38-L-38-L-P-28-PN-NNN-NNN H1P165RCAA5C2ND8GG3NNL38L38LP28PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D8-G-G3-NN-L-35-L-28-L-P-24-PN-NNN-NNN H1P165RCAA5C2ND8GG3NNL35L28LP24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D8-G-G3-H6-L-35-L-35-L-P-24-PN-NNN-NNN H1P165RCAA5C2ND8GG3H6L35L35LP24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D8-G-G3-H5-L-42-L-42-L-P-24-PN-NNN-NNN H1P165RCAA5C2ND8GG3H5L42L42LP24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D8-G-G3-H2-L-42-L-42-L-P-24-PN-NNN-NNN H1P165RCAA5C2ND8GG3H2L42L42LP24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D8-G-G2-H6-L-38-L-38-L-P-24-PN-NNN-NNN H1P165RCAA5C2ND8GG2H6L38L38LP24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D7-G-G3-H4-L-45-L-45-L-P-24-PN-NNN-NNN H1P165RCAA5C2ND7GG3H4L45L45LP24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D7-G-G2-H4-L-42-L-42-L-P-24-PN-NNN-NNN H1P165RCAA5C2ND7GG2H4L42L42LP24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D7-G-G2-H4-L-38-L-38-N-E-24-PN-NNN-NNN H1P165RCAA5C2ND7GG2H4L38L38NE24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D6-G-G3-NN-L-35-L-35-A-L-24-PN-NNN-NNN H1P165RCAA5C2ND6GG3NNL35L35AL24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D6-G-G3-NN-L-30-L-30-L-L-24-PN-NNN-NNN H1P165RCAA5C2ND6GG3NNL30L30LL24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D6-G-G2-H6-L-42-L-42-L-L-24-PN-NNN-NNN H1P165RCAA5C2ND6GG2H6L42L42LL24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D6-G-G2-H6-L-40-L-40-L-L-20-PN-NNN-NNN H1P165RCAA5C2ND6GG2H6L40L40LL20PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D6-G-G2-H3-L-30-L-30-L-L-28-PN-NNN-NNN H1P165RCAA5C2ND6GG2H3L30L30LL28PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D6-G-G2-H2-L-38-L-38-L-L-24-PN-NNN-NNN H1P165RCAA5C2ND6GG2H2L38L38LL24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D5-L-G3-H4-L-38-L-38-L-M-26-P4-NNN-NNN H1P165RCAA5C2ND5LG3H4L38L38LM26P4NNNNNN
H1-P-165-R-C-A-A5-C2-N-D5-G-G2-H4-L-35-L-35-L-M-24-PN-NNN-NNN H1P165RCAA5C2ND5GG2H4L35L35LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D5-G-G2-H4-L-33-L-33-L-M-24-PN-NNN-NNN H1P165RCAA5C2ND5GG2H4L33L33LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D5-G-G2-H4-L-20-L-35-L-M-26-PN-NNN-NNN H1P165RCAA5C2ND5GG2H4L20L35LM26PNNNNNNN

5. Select the appropriate accumulator type:
Choose the appropriate accumulator type based on your specific application and space constraints. Common types include bladder accumulators, piston accumulators, and diaphragm accumulators.

6. Check safety factors:
Consider adding a safety factor to the calculated accumulator capacity to account for changes and ensure the accumulator can effectively handle the demands of the system.

7. Consider space and installation limitations:
Ensure that the selected accumulator can be physically installed within the available space and can be properly integrated into the hydraulic system.

8.Select the accumulator selection software:
There are a variety of totalizer sizing software tools available that can assist with calculations and help you select the right totalizer for your specific needs. These tools also provide guidance on accumulator type selection and installation.

9. Installation and testing:
After selecting an accumulator, follow the manufacturer's guidelines for installing it in the hydraulic system.
Testing is performed to ensure that the accumulator is effectively reducing pulsation and that the system is operating within required parameters.

10. Maintenance and monitoring:
Check and maintain the accumulator regularly to ensure it is working properly. This includes checking for leaks, monitoring precharge pressure (in the case of a gas-charged accumulator) and replacing any worn parts.

11. Fluid type and temperature:
The type of hydraulic oil and its temperature influence accumulator selection. Certain fluids may require special materials or designs to ensure compatibility and long-term reliability.

12.Response time:
Consider the required response time of the accumulator. Some applications may require a fast response to pressure changes, while others can tolerate slower response times.

13. System integration:
Ensure the accumulator is effectively integrated into the hydraulic system. To optimize its performance, appropriate piping, pressure relief valves and control systems may be required.
H1-P-165-R-C-A-A5-C2-N-D3-L-G3-H3-L-38-L-38-L-M-26-P4-NNN-NNN H1P165RCAA5C2ND3LG3H3L38L38LM26P4NNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-G3-H3-L-42-L-42-L-M-28-PN-NNN-NNN H1P165RCAA5C2ND3GG3H3L42L42LM28PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-G3-H3-L-42-L-42-A-N-28-PN-NNN-NNN H1P165RCAA5C2ND3GG3H3L42L42AN28PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-G3-H3-L-42-L-42-A-M-28-PN-NNN-NNN H1P165RCAA5C2ND3GG3H3L42L42AM28PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-G2-H6-L-30-L-20-L-M-24-PN-NNN-NNN H1P165RCAA5C2ND3GG2H6L30L20LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-G2-H2-L-40-L-40-L-M-24-PN-NNN-NNN H1P165RCAA5C2ND3GG2H2L40L40LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-G2-E5-L-35-L-35-L-M-24-PN-NNN-NNN H1P165RCAA5C2ND3GG2E5L35L35LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-F3-NN-L-35-L-35-A-M-24-PN-NNN-NNN H1P165RCAA5C2ND3GF3NNL35L35AM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-F3-NN-L-33-L-33-A-M-24-PN-NNN-NNN H1P165RCAA5C2ND3GF3NNL33L33AM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-F3-NN-L-25-L-25-A-M-24-PN-NNN-NNN H1P165RCAA5C2ND3GF3NNL25L25AM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-N-D3-G-F3-H6-L-28-L-28-A-M-24-PN-NNN-NNN H1P165RCAA5C2ND3GF3H6L28L28AM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D8-G-G3-NN-L-25-L-25-A-P-20-PN-NNN-NNN H1P165RCAA5C2BD8GG3NNL25L25AP20PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D6-G-G2-H5-K-38-K-38-L-L-24-PN-NNN-NNN H1P165RCAA5C2BD6GG2H5K38K38LL24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D6-G-G2-E5-L-45-L-45-L-L-20-PN-NNN-NNN H1P165RCAA5C2BD6GG2E5L45L45LL20PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D5-G-G2-H4-L-38-L-38-L-M-24-PN-NNN-NNN H1P165RCAA5C2BD5GG2H4L38L38LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D5-G-G2-H4-L-35-L-35-L-M-24-PN-NNN-NNN H1P165RCAA5C2BD5GG2H4L35L35LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D5-G-G2-H4-K-38-K-38-L-M-26-PN-NNN-NNN H1P165RCAA5C2BD5GG2H4K38K38LM26PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D3-G-G3-NN-L-45-L-45-L-M-24-PN-NNN-NNN H1P165RCAA5C2BD3GG3NNL45L45LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D3-G-G3-NN-L-42-L-42-A-M-28-PN-NNN-NNN H1P165RCAA5C2BD3GG3NNL42L42AM28PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D3-G-G3-H3-K-38-K-38-L-M-26-PN-NNN-NNN H1P165RCAA5C2BD3GG3H3K38K38LM26PNNNNNNN

14.Environmental conditions:
Consider the environmental conditions in which the hydraulic system operates. Extreme temperatures, contamination or corrosive environments can affect accumulator performance and life.

15. Legal and safety requirements:
Relevant legal and safety standards must be observed when designing and installing hydraulic systems and accumulators. Regulations may vary by location and application.

16. Real world testing:
Practical tests are carried out to verify the performance of selected accumulators under actual operating conditions. This will help ensure that it effectively absorbs pulsations and provides the required reduction in pressure fluctuations.

17. Cost considerations:
Evaluate the cost of the accumulator and the overall impact on the project budget. Consider whether the selected battery capacity and type fit within your budget constraints.

2.jpg

18. Documentation and record keeping:
Maintain comprehensive documentation of accumulator specifications, installation details and maintenance records. This information will be invaluable for future troubleshooting and maintenance.

19. Dynamic load changes:
If your hydraulic system experiences dynamic load changes or rapid changes in demand, you may need a larger accumulator to effectively handle these fluctuations. Consider worst-case scenarios to ensure that the accumulator can adapt to these changes.

20. Multiple accumulators:
In some cases it may be beneficial to use multiple accumulators in a parallel or staged configuration to provide more effective pulsation reduction. This can help distribute load and improve overall system performance.

21. Pulsation damper:
In addition to accumulators, consider using pulsation dampers or shock absorbers in hydraulic systems. These devices can be placed in specific locations to target and reduce pressure pulsations at critical points in the system.

22.Continuous monitoring and adjustment:
Hydraulic systems can change over time due to wear and component degradation. Monitor system performance regularly and adjust accumulator capacity or configuration as necessary to maintain optimal pulsation reduction.
H1-P-165-R-C-A-A5-C2-B-D3-G-G3-H2-L-38-L-38-L-M-24-PN-NNN-NNN H1P165RCAA5C2BD3GG3H2L38L38LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D3-G-G2-H6-L-45-L-45-L-M-24-PN-NNN-NNN H1P165RCAA5C2BD3GG2H6L45L45LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D3-G-G2-H3-L-40-L-33-L-M-24-PN-NNN-NNN H1P165RCAA5C2BD3GG2H3L40L33LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D3-G-G2-H3-L-38-L-38-L-M-24-PN-NNN-NNN H1P165RCAA5C2BD3GG2H3L38L38LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D3-G-G2-H2-L-38-L-38-L-M-24-PN-NNN-NNN H1P165RCAA5C2BD3GG2H2L38L38LM24PNNNNNNN
H1-P-165-R-C-A-A5-C2-B-D3-G-F3-NN-L-42-L-42-L-M-28-PN-NNN-NNN H1P165RCAA5C2BD3GF3NNL42L42LM28PNNNNNNN
H1-P-165-R-C-A-A5-C1-N-D5-G-G2-H4-L-25-L-25-L-M-24-PN-NNN-NNN H1P165RCAA5C1ND5GG2H4L25L25LM24PNNNNNNN
H1-P-165-R-C-A-A5-C1-N-D3-G-G3-NN-L-25-L-25-L-M-24-PN-NNN-NNN H1P165RCAA5C1ND3GG3NNL25L25LM24PNNNNNNN
H1-P-165-R-C-A-A5-C1-N-D3-G-G3-H3-L-42-L-42-A-M-28-PN-NNN-NNN H1P165RCAA5C1ND3GG3H3L42L42AM28PNNNNNNN
H1-P-165-R-C-A-A5-C1-N-D3-G-G3-H3-L-42-L-42-A-M-24-PN-NNN-NNN H1P165RCAA5C1ND3GG3H3L42L42AM24PNNNNNNN
H1-P-165-R-C-A-A5-C1-N-D3-G-G2-H5-L-35-L-35-A-M-24-PN-NNN-NNN H1P165RCAA5C1ND3GG2H5L35L35AM24PNNNNNNN
H1-P-165-R-C-A-A5-C1-B-D8-G-G3-H6-L-45-L-45-L-P-24-PN-NNN-NNN H1P165RCAA5C1BD8GG3H6L45L45LP24PNNNNNNN
H1-P-165-R-C-A-A5-C1-B-D6-L-G2-NN-L-33-L-33-L-L-24-P4-NNN-NNN H1P165RCAA5C1BD6LG2NNL33L33LL24P4NNNNNN
H1-P-165-R-C-A-A5-C1-B-D6-L-G2-H6-L-33-L-33-L-L-24-P4-NNN-NNN H1P165RCAA5C1BD6LG2H6L33L33LL24P4NNNNNN
H1-P-165-R-C-A-A5-C1-B-D6-L-G2-H5-L-33-L-33-L-L-24-P4-NNN-NNN H1P165RCAA5C1BD6LG2H5L33L33LL24P4NNNNNN
H1-P-165-R-C-A-A5-C1-B-D6-L-G2-H3-L-33-L-33-L-L-24-P4-NNN-NNN H1P165RCAA5C1BD6LG2H3L33L33LL24P4NNNNNN
H1-P-165-R-C-A-A5-C1-B-D5-G-G2-H4-L-40-L-40-L-M-24-PN-NNN-NNN H1P165RCAA5C1BD5GG2H4L40L40LM24PNNNNNNN
H1-P-165-R-C-A-A5-C1-B-D3-G-G3-H2-L-40-L-40-L-M-24-PN-NNN-NNN H1P165RCAA5C1BD3GG3H2L40L40LM24PNNNNNNN
H1-P-165-R-C-A-A5-C1-B-D3-G-G2-H6-L-33-L-33-L-M-24-PN-NNN-NNN H1P165RCAA5C1BD3GG2H6L33L33LM24PNNNNNNN
H1-P-165-R-C-A-A4-C3-N-D8-G-G3-H3-L-42-L-42-N-E-24-PN-NNN-NNN H1P165RCAA4C3ND8GG3H3L42L42NE24PNNNNNNN

23. Customized solutions:
For specialized or unique applications, it may be necessary to consult with a hydraulic systems engineer or accumulator manufacturer to design a custom solution that fits your specific requirements.

24. Training and expertise:
Ensure that personnel responsible for designing, installing and maintaining hydraulic systems have appropriate training and the necessary expertise. This will help prevent common errors and ensure the system operates safely and efficiently.

25. Energy efficiency:
Consider the energy efficiency of your hydraulic system. Oversizing the accumulator results in energy losses and reduced efficiency. Striking a balance between effective pulsation reduction and energy consumption is crucial.

26. Documentation and risk assessment:
Conduct a risk assessment to identify potential issues that may affect accumulator performance. Properly record all calculations and design decisions for future reference and safety compliance.

27. Consultation and testing:
When in doubt, consult a hydraulics expert and, if possible, perform system testing to verify accumulator sizing and pulsation reduction. Real-world data is invaluable for optimizing system performance.

Keep in mind that the specific requirements for estimating accumulator capacity can vary significantly depending on the characteristics, application, and performance goals of the hydraulic system. Careful consideration of these factors, and consultation with experts and manufacturers, will help you make the best choice for your hydraulic system, ensuring it operates smoothly and efficiently while effectively reducing pressure pulsations.

This article is published by the official website of Baolilai Hydraulics, please contact the author and indicate the source for reprinting:https://www.baolilai-pump.cn/news/1144.html

Tel:13600066458