The properties of the oil used in an axial piston pump can significantly affect the flow pulsation behavior of the pump

The properties of the oil used in an axial piston pump can significantly affect the flow pulsation behavior of the pump. Here are some key factors to consider: 1. Viscosity: The viscosity of the oil affects the flow resistance in the pump. Higher viscosity oils dampen flow pulsations, reducing their amplitude. However, too high a viscosity can also increase friction losses and reduce pump efficiency. It is important to select an oil viscosity that balances flow pulsation control with overall pump performance. 2. Shear stability: The shear stability of an oil refers to its ability to maintain viscosity under shear force. In an axial piston pump, the oil experiences high shear rates between moving parts such as the piston and cylinder bore. If the oil undergoes significant viscosity changes due to shear, it will affect the flow pulsation characteristics. Therefore, using an oil with good shear stability helps minimize the effect of shear on flow pulsation. 3. Compressibility: The compressibility of oil plays an important role in the formation and transmission of pressure waves in the pump. Highly compressible oils cause greater pressure changes and flow pulsations. It is desirable to use an oil with low compressibility to reduce flow pulsation and ensure stable pump operation. 4. Lubrication performance: The lubrication performance of oil will affect the friction between moving parts, thus affecting the flow pulsation behavior. Good lubrication reduces friction and wear, resulting in smoother operation and potentially less flow pulsation. Choosing an oil with the proper lubricating properties will help maintain consistent pump performance. 90L130-KP-5-CD-80-R-3-F1-H-00-GBA-35-35-24 90L130KP5CD80R3F1H00GBA353524 90-L-130-KP-5-CD-80-R-3-F1-H-00-GBA-35-35-24 90L130KP5CD80R3F1H00GBA353524 90L130-KP-5-CD-80-R-3-F1-H-03-GBA-29-29-24 90L130KP5CD80R3F1H03GBA292924 90-L-130-KP-5-CD-80-R-3-F1-H-03-GBA-29-29-24 90L130KP5CD80R3F1H03GBA292924 90L130-KP-5-CD-80-R-3-F1-H-03-GBA-35-35-24 90L130KP5CD80R3F1H03GBA353524 90-L-130-KP-5-CD-80-R-3-F1-H-03-GBA-35-35-24 90L130KP5CD80R3F1H03GBA353524 90L130-KP-5-CD-80-R-3-F1-H-03-GBA-35-35-30 90L130KP5CD80R3F1H03GBA353530 90-L-130-KP-5-CD-80-R-3-F1-H-03-GBA-35-35-30 90L130KP5CD80R3F1H03GBA353530 90L130-KP-5-CD-80-R-3-F1-H-06-GBA-35-35-30 90L130KP5CD80R3F1H06GBA353530 90-L-130-KP-5-CD-80-R-3-F1-H-06-GBA-35-35-30 90L130KP5CD80R3F1H06GBA353530 5. Damping additives: Some oils may contain additives designed to enhance damping performance. These additives can help reduce flow pulsation by dissipating energy within the pump and damping pressure waves. Consider using oils with suitable damping additives to dampen flow pulsations and minimize impact on system performance. 6. Pollution and degradation: Pollutants and oil degradation products can affect the flow pulsation characteristics of the pump. Particulates or degraded components in the oil can clog or interfere with the internal flow passages of the pump, resulting in increased flow pulsation. It is important to maintain clean and properly filtered oil to minimize the possibility of flow pulsation disturbances. 7. Temperature Sensitivity: Oil viscosity index and temperature sensitivity can affect flow pulsation behavior. Changes in temperature cause changes in viscosity, which in turn affect flow resistance and flow pulsation. Understanding the temperature sensitivity of the oil and considering its effect on flow pulsation characteristics is critical to maintaining stable pump operation. 8. Oil pressure: The oil pressure in the pump will affect the flow pulsation behavior. Higher oil pressures typically result in increased flow pulsation due to higher peak pressures and flow rate variations. It is important to consider the operating pressure range of the pump and select an oil with the proper characteristics to minimize flow pulsation within that range. 9. Air content in oil: Air entrained in oil can significantly affect flow pulsation behavior. When air bubbles are present in the oil, they compress and expand at different pressures, causing flow to pulsate. Minimizing air entrainment in oil is critical by using effective degassing techniques or selecting oils with low air content to reduce flow pulsation. 10. Oil temperature: Oil temperature will affect its viscosity and overall flow characteristics, which in turn will affect flow pulsation characteristics. Variations in oil temperature affect the density and viscosity of the oil, resulting in variations in flow pulsation. The temperature sensitivity of the oil and its effect on flow pulsations must be considered during system design and operation. 11. Oil Sealing and Sealing: Proper sealing and sealing of the oil within the pump system is critical to maintaining stable flow characteristics and minimizing flow pulsation. Oil leaks or bypasses can disrupt flow patterns, resulting in irregular flow pulsations. Ensure effective sealing measures and maintain proper lubrication to minimize the effect of oil leakage on flow pulsation. 12. Oil Aging and Maintenance: Oil degrades over time, causing its properties to change and deposits or contaminants to form. Deteriorated oil will affect the internal clearance and flow passage of the pump, thereby affecting the flow pulsation. Regular oil analysis and maintenance, such as oil filtration and changes, help maintain consistent oil characteristics and minimize the possibility of flow pulsation disturbances. 90L130-KP-5-CD-80-S-3-F1-H-03-GBA-29-29-24 90L130KP5CD80S3F1H03GBA292924 90-L-130-KP-5-CD-80-S-3-F1-H-03-GBA-29-29-24 90L130KP5CD80S3F1H03GBA292924 90L130-KP-5-CD-80-S-4-F1-H-03-GBA-29-29-24 90L130KP5CD80S4F1H03GBA292924 90-L-130-KP-5-CD-80-S-4-F1-H-03-GBA-29-29-24 90L130KP5CD80S4F1H03GBA292924 90L130-KP-5-DE-80-L-3-F1-H-03-GBA-35-35-24 90L130KP5DE80L3F1H03GBA353524 90-L-130-KP-5-DE-80-L-3-F1-H-03-GBA-35-35-24 90L130KP5DE80L3F1H03GBA353524 90L130-KP-5-DE-80-L-3-F1-H-05-GBA-45-45-24 90L130KP5DE80L3F1H05GBA454524 90-L-130-KP-5-DE-80-L-3-F1-H-05-GBA-45-45-24 90L130KP5DE80L3F1H05GBA454524 90L130-KP-5-DE-80-P-3-C8-F-03-GBA-35-35-24 90L130KP5DE80P3C8F03GBA353524 90-L-130-KP-5-DE-80-P-3-C8-F-03-GBA-35-35-24 90L130KP5DE80P3C8F03GBA353524 13. System design considerations: The pump design itself plays a vital role in the flow pulsation characteristics. Factors such as number of pistons, piston phasing, port design, and valve dynamics can significantly affect flow pulsation. These factors interact with the properties of the oil and require a comprehensive analysis of the pump design, including its interaction with the selected oil, to understand and control flow pulsation behavior. 14. Experimental verification: In order to fully understand the influence of oil characteristics on flow pulsation, experimental testing is recommended. Real-world testing can provide valuable data on flow pulsation under different oil conditions and verify the impact of oil properties. Experimental validation allows optimization of the pump oil system and fine-tuning of oil selection to achieve the desired flow pulsation control. By considering these points and performing thorough analysis, experimentation, and optimization, you can effectively understand and manage the effect of oil properties on flow pulsation in axial piston pumps. This knowledge can aid in the design and operation of pump systems, optimizing their performance and minimizing problems associated with flow pulsation.

This article is published by the official website of Baolilai Hydraulics, please contact the author and indicate the source for reprinting:https://www.baolilai-pump.cn/news/647.html

Tel:13600066458