    2. Applicable Scene

    Cavitation is a common issue that can occur in hydraulic systems, including those utilizing Sauer Danfoss hydraulic pumps. It can lead to reduced efficiency, increased wear, and ultimately, pump failure. Understanding the causes of cavitation and implementing effective solutions is crucial for maintaining optimal performance and extending the lifespan of your hydraulic pump. Here are several strategies to address cavitation problems in Sauer Danfoss hydraulic pumps:
    90-L-130-HS-5-NN-80-R-4-C8-F-03-GBA-32-32-24
    90L130HS5NN80R4C8F03GBA323224
    Identify the Causes of Cavitation: The first step in fixing cavitation issues is to identify the root causes. Common causes include low fluid levels in the reservoir, high fluid temperatures, improper pump installation, and excessive demand on the hydraulic system. Each of these factors can cause the pressure in the pump to drop below the vapor pressure of the hydraulic fluid, leading to cavitation.
    90L130 hydraulic pump
    83001067
    Maintain Proper Fluid Levels: Ensure that the hydraulic fluid reservoir is adequately filled. Low fluid levels can lead to suction issues, increasing the risk of cavitation. Regularly check and top off the fluid levels as needed, adhering to the manufacturer’s specifications for optimal operation.
    Monitor Fluid Temperature: High temperatures can lower the viscosity of hydraulic fluids, making them more prone to cavitation. Implement cooling solutions, such as heat exchangers or coolers, to maintain fluid temperature within the recommended range. Additionally, consider using hydraulic fluids with higher boiling points to mitigate cavitation effects.
    Optimize Pump Installation: Ensure that the hydraulic pump is installed correctly according to the manufacturer’s guidelines. This includes proper alignment, minimizing the length and bends of suction lines, and using appropriate fittings. A well-installed pump will enhance performance and decrease the likelihood of cavitation.